- Active Sub-Slab Depressurization (ASD) Core Drill, Suction Pit & Fan$890 – $1,040
- Heavy-Duty Gasketed Lexan Polycarbonate Sump Cover + View Port+$100 – $150
- U-Tube Manometer Vacuum Gauge, System Labels & 48-Hr CRM Clearance TestIncluded
Post-2000 Wentzville subdivisions sit on 4" of clean crushed limestone under the slab and connect to perimeter drain tile. Pulling vacuum at the sump pit depressurizes the entire footprint with a single quiet 60W fan.
| Jurisdiction / Metric | Verified Reading / Share | EPA / WHO Benchmark | Real Estate & Health Implication | Recommended Action |
|---|---|---|---|---|
| St. Charles County 2023 Test Failure Rate | 40.8% of tests ≥ 4.0 pCi/L (MO DHSS) | 4.0 pCi/L EPA Action Level | Over 2 in 5 reported county tests trigger buyer inspection repair requests | Active Sub-Slab Mitigation |
| St. Charles Co. Cumulative DHSS (3,995 Tests) | 3.8 pCi/L Mean · 29.3% ≥ 4.0 · 204.0 Max | 4.0 pCi/L EPA / 2.7 WHO | County mean sits at the action threshold; extreme hotspots exceed 100+ pCi/L | 48-Hr CRM Test Every Home |
| EPA Radon Zone Classification | EPA Zone 2 (2.0 – 4.0 pCi/L predicted avg) | Fix ≥ 4.0 · Consider 2.0–4.0 | EPA explicitly advises considering mitigation between 2.0 and 4.0 pCi/L | Mitigate ≥ 4.0 (Consider ≥ 2.7) |
| Wentzville ZIP 63385 Modeled Basement Mean | 2.0 ± 0.07 pCi/L Basement / 1.3 pCi/L Upstairs | 0.4 pCi/L Outdoor Baseline | 5× outdoor background average; finished basement bedrooms/offices get peak dose | Test Lowest Livable Level |
| Lake St. Louis / O'Fallon Border (63367 / 63366) | 2.4 ± 0.08 pCi/L (63367) / 2.0 pCi/L (63366) | 2.7 pCi/L WHO Reference | Higher limestone ridge elevation along I-70 / Hwy N & Hwy DD corridor | Sump Seal + ASD System |
| Post-Mitigation ASD System Output | 0.4 – 1.4 pCi/L (Guaranteed < 2.0 pCi/L) | Clears VA / FHA / Conventional | Satisfies all St. Louis Association of Realtors (SLAR) inspection riders | Cleared for Closing |
| Wentzville Neighborhoods | Typical Foundation & Sub-Slab Bed | HOA & Aesthetic Exhaust Preference | Standard Fan & Price Tier |
|---|---|---|---|
| Stone Meadows · Wyndgate · Bear Creek | 2000s–2020s poured concrete basement, 4" crushed limestone gravel, polyethylene sump pit | Side/rear sidewall exit painted to match siding/downspout OR garage-attic roof exit | RadonAway RP145 + Lexan Sump Lid ($990 – $1,240) |
| Peruque Valley · Peine Lakes · Great Oaks | Larger 1,600–2,400+ sq ft ranch & 2-story basements with interior drain tile loops | Hidden garage-attic routing through passive roof boot preferred by strict HOAs | RP145 or RP265 + Attic Roof Exit ($1,190 – $1,450) |
| Historic Wentzville · Foristell Border (63348) | Pre-1995 poured/block foundations over denser clay or compacted soil | Exterior sidewall Sch 40 PVC with high-suction fan | RadonAway GP501 High-Suction ($1,090 – $1,350) |
| Walk-Out & Split-Level Homes w/ Crawlspace | Combination poured basement + unvented dirt/gravel crawlspace zone | Dual-branch suction: basement sump pit + 12-mil sealed crawlspace vapor barrier | ASD + Crawlspace Encapsulation Tie-In ($1,390 – $1,790) |
| Indoor Radon Reading | Cigarette Equivalent (EPA) | 200 Chest X-Ray Equiv./Yr |
|---|---|---|
| 4.0 pCi/L (EPA Action) | ~8 cigarettes / day | ~200 chest X-rays / yr |
| 8.0 pCi/L (Common Fail) | ~16 cigarettes / day (nearly 1 pack) | ~400 chest X-rays / yr |
| 20.0 pCi/L (High Hotspot) | ~2 packs of cigarettes / day | ~1,000 chest X-rays / yr |